Updated 2026-11-16
Scan speed is the wrong place to start. What decides whether a body scanner fits your workflow is range limits, how accuracy is defined, group-measurement support, software integration, and the 0.6 m standing zone.
Before comparing scan times, ask three questions: how wide a range of heights and weights do you actually serve, under what conditions is the accuracy figure specified, and can the captured data enter the workflow you already run. Two devices with near-identical spec sheets usually differ not by two seconds of scan time but by range limits, group-measurement support, and whether the report can be adapted to your programme. The five parameters below are worth having confirmed in writing.
Take the medical body-scan mirror XK-TZSJ as a reference. Nominal values: height 110–200 cm, weight 10–200 kg, body-fat estimation for ages 10–70, working distance 0.6–0.75 m (0.6 m optimal). One device therefore covers children and adults without a second unit.
Three boundaries to check:
A ±1 mm figure can mean three different things: repeatability of a static measurement, single-point absolute error, or maximum deviation across a whole distance range. On site they behave nothing alike.
Ask for four things in writing: the definition, the calibration method and the artefact used, the calibration interval, and whether a calibration report ships with the unit. A device in a showroom and a device at the end of a corridor with strong backlight will not produce identical results — and if this is not in the contract, it is very hard to raise later.
This is the parameter most often skipped, because a standard demonstration never exercises it. The medical body-scan mirror supports group measurement at scale, with backend-triggered enrolment and barcode-scanner login. On the retail edition it is a paid add-on.
The test is simple. If your use case is a school check, a community clinic day or a corporate screening — hundreds of people in one day — group measurement is a hard requirement, and you should watch the continuous enrolment flow demonstrated end to end. For one-to-one walk-in use, it can wait.
The question most often forgotten is whether the report can be changed — template, fonts, institution name in the footer, recommendation rules. That one answer decides whether the device sits in the lobby as a demo or becomes part of your service package and sales flow.
Body 1760 × 500 × 40 mm, turntable 450 mm in diameter and 91 mm high, minimum footprint about 1.7 m², net weight about 32.5 kg (45 kg shipping), 32-inch touchscreen, 100–240 V 50/60 Hz.
Leave 0.6–0.75 m of clear standing space in front of the mirror, and avoid strong backlight behind the subject. Bring a tape measure and check the site once — it is more useful than any rendering.
| Dimension | XK-TZSJ Medical | XK-H003 Retail | XK-CH003 Research |
|---|---|---|---|
| Certification | Class II medical-device registration | No medical registration | No medical registration |
| Range | Height 110–200 cm, weight 10–200 kg, body fat age 10–70 | Height 110–200 cm, weight 10–200 kg | Height 110–200 cm |
| Capture | Infrared structured light, millisecond dynamic capture, about 2 million points | Full-body scan in 20 seconds | Same capture hardware as the medical edition |
| Report | Posture, spine, body composition, girth | 128-item visual report in about one minute | Raw data plus 3D model |
| Software | Medical software included, on-premise, HIS integration | Store CRM, preference questionnaire, AI pillow and mattress selection | Batch download, custom export, API |
| Group measurement | Supported at scale | Paid add-on | Supported at scale |
| Model export | STL / OBJ, 1:1 3D model | Raw point cloud, about 2 million points | Batch export and API access |
| Typical users | Hospitals, maternal and child centres, community health, TCM clinics | Retail and service businesses | Universities and research institutes |
Run through these six and sign them off on the spot. None is complicated; all of them are painful to do afterwards.
Only after these six does the device count as delivered. Signing off after a demonstration is the single most common source of later disputes.
Give the account manager three pieces of information: site dimensions including door width, client mix by age band and main concern, and the systems you need to connect (HIS, membership, POS). Configuration follows from those three. Cooperation runs either as direct purchase or through a dealer arrangement; details are discussed directly.
Submit an inquiry · See all device models
Note on figures: parameters come from Xianku product documentation and published nominal values. Accuracy figures are manufacturer claims; final delivery follows on-site calibration and the contract. This article contains no pricing.
The accuracy figures and posture data discussed here all rest on the same measurement conditions: the person wears close-fitting clothing or shorts, is barefoot, stands naturally, stays as still as possible during the scan (about 3–5 seconds), and has hair tied back or pinned up so it does not cover the head and shoulder outline.
When these conditions are met, the data is used for preliminary screening, risk indication and follow-up comparison of posture and spinal status; when they are not met (loose clothing, movement, hair covering the outline), the result is an estimate for reference only. The device does not provide a medical diagnosis — any abnormal finding needs review at a medical institution.
Accuracy is millimetre-level (vendor nominal ±1 mm). A living body is not a calibration artefact: millimetre-level variation across three consecutive scans of the same person is normal, so read the trend from the range of several measurements rather than from a single number.
Specifications here come from the device datasheet and user manual — nothing is estimated or inferred.
Case data comes from client project records; organization names can be verified by phone. We do not use client names without authorization.
Qualification records can be looked up by certificate number in the National Medical Products Administration database.
Tell us how your organization works and we will route you to the manager for your sector.
If this article helped, leave your organisation and contact details and we will put together how similar institutions have handled it.
Within 30 minutes of your submission, the account manager for your sector will call you
No prices are published on this site; configuration and commercial terms are discussed one-to-one with your account manager