Updated 2026-11-16
Devices rarely break suddenly; they drift slowly. Five minutes a day, half an hour a month, one system check a year — plus the rules for what to do after moving, renovating or updating.
A device does not fail suddenly. It drifts. Half a millimetre today, two millimetres in three months, and the report looks normal throughout — until a follow-up finds that last time's data does not match. That is what calibration and maintenance are for: catching drift before it causes trouble.
No complex instruments are needed. Three cycles, three sets of actions: five minutes daily, half an hour monthly, one system check yearly.
Tick these off on a daily sheet. Leave one column for an anomaly note — one sentence is enough, and it is valuable during later investigation.
The daily check asks "is anything obviously wrong". The monthly check asks "is it still accurate". Method: on the same day each month, at the same time, capture the same colleague three times under standard conditions and compare the same dimension.
Where possible, keep a calibration artefact — a block of known dimensions. It removes the human variable and shows the device directly. Without one, the fixed-person method gets close enough.
The annual service covers four things: optical path and lens inspection, mechanical fastening, software version verification and full functional re-testing. The first three can be done on site; the fourth follows the manufacturer's procedure.
Return the unit, or have the manufacturer calibrate on site, if any of the following occurs — do not "adjust it a bit and carry on":
The impact of these three is badly underestimated. Renovation dust settles on lenses and optical windows; a new room means new light, floor and power; slight deformation during transport is invisible.
The rule is simple: if the device has left its position, redo the monthly procedure. Compare against the data from before the move, and only continue using it for reports if the difference falls within an acceptable range. Half an hour here avoids months of hidden bias.
| Field | Content |
|---|---|
| Date and person | Named individual, not "the department". |
| Action type | Daily, monthly, yearly, post-move re-check, post-update re-check. |
| Key result | The three repeatability values, or the self-check conclusion. |
| Anomaly and handling | What was found, what was done, whether it recovered. |
| Version information | Software and firmware version numbers. |
This table lives as long as the device. Transfer, warranty renewal, inspection and any question about whether a particular report can be trusted all depend on it.
Maintenance records are not only for the equipment manager. They determine how far a report can be trusted.
Consider a follow-up where someone's data differs noticeably from six months ago. Has the body really changed, or has the device drifted? With complete monthly records, post-move re-checks and version history, the question is answered on the spot. Without them, the answer becomes vague — and vague conclusions are what clients remember.
Maintenance is also a supply-chain arrangement. Three things worth confirming at purchase: the consumable and wear-part list with recommended stock, the fault response time, and the repair turnaround. Settle these and downtime becomes predictable.
What institutions fear is not a breakdown but not knowing how long it will last. Writing the response time into the contract is more useful than asking for an extra year of warranty.
The first is how the lens is cleaned. Wiping the optical window dry with tissue leaves fine scratches over time, which show up as localised burring in the point cloud. Use the cleaning cloth and solution specified in the manual, and do not breathe on the window. Ten seconds a day — yet most institutions read the manual for the first time only after a problem appears.
The second is environmental change. The device has not moved, but the room has: a new spotlight, lighter floor tiles, a high-draw machine installed nearby, a reflective film added to the window. None of these triggers a warning, and all of them change the result. Glancing around the room during the monthly check is the highest-value single step in this article.
Good calibration and maintenance keep the device stable. They do not change the inherent preconditions of measuring a living body. Values captured outside standard conditions — close-fitting clothing, bare feet, natural standing, several seconds still, hair tied low — remain suitable only for initial screening and risk indication, not as measurement conclusions. This is a limit of the method, not of the equipment's condition.
If you need a maintenance schedule template or the spare-parts list for a specific model, contact the account manager. Cooperation runs as direct purchase or through a dealer arrangement; details are discussed directly.
Submit an inquiry · See device models
Note on figures: this article describes general practice; follow the maintenance manual shipped with your unit. Cleaning methods and calibration intervals are those specified by the manufacturer. This article contains no pricing.
The accuracy figures and posture data discussed here all rest on the same measurement conditions: the person wears close-fitting clothing or shorts, is barefoot, stands naturally, stays as still as possible during the scan (about 3–5 seconds), and has hair tied back or pinned up so it does not cover the head and shoulder outline.
When these conditions are met, the data is used for preliminary screening, risk indication and follow-up comparison of posture and spinal status; when they are not met (loose clothing, movement, hair covering the outline), the result is an estimate for reference only. The device does not provide a medical diagnosis — any abnormal finding needs review at a medical institution.
Accuracy is millimetre-level (vendor nominal ±1 mm). A living body is not a calibration artefact: millimetre-level variation across three consecutive scans of the same person is normal, so read the trend from the range of several measurements rather than from a single number.
Specifications here come from the device datasheet and user manual — nothing is estimated or inferred.
Case data comes from client project records; organization names can be verified by phone. We do not use client names without authorization.
Qualification records can be looked up by certificate number in the National Medical Products Administration database.
Tell us how your organization works and we will route you to the manager for your sector.
If this article helped, leave your organisation and contact details and we will put together how similar institutions have handled it.
Within 30 minutes of your submission, the account manager for your sector will call you
No prices are published on this site; configuration and commercial terms are discussed one-to-one with your account manager