Having a certificate is not the same as the certificate matching your device. Four fields decide it: registration number, model, product composition and validity. Production and distribution licences are separate.
When buying medical equipment, "we have the certificate" comes up almost every time. But the certificate is not the conclusion. Whether the certificate matches the device you are buying is the conclusion. Verification is the work of turning "we have a certificate" into "this device's certificate matches".
It does not require specialist knowledge. It requires patience: four fields compared character by character, two licences kept distinct, and one inconsistency pursued until it is answered.
| Field | What to check |
|---|---|
| Registration number | Format and digit count. The classification code inside the number indicates the management class; Class II and Class III follow different numbering rules. |
| Model and specification | Must match the nameplate, the manual and the contract exactly, including any suffix. Manufacturers often run several models on one platform; only the model listed on the certificate is covered. |
| Product composition | The certificate annex states which parts make up the product: main unit, software, accessories. If the software is a separate component, check whether it appears in the composition. |
| Validity | Certificates expire and must be renewed. Check once before signing the contract and again on delivery — the date can fall in between. |
Model and composition are where problems concentrate. A different suffix usually means a different scope of application; software absent from the composition means that software is not part of the certified product. These two inconsistencies are the source of most later disputes.
Where the three disagree, the official record prevails, and the supplier should explain the difference in writing. If the explanation is unclear, do not sign yet.
One line to remember: the registration certificate governs the product, the production licence governs manufacturing, the distribution licence or filing governs selling. Three documents, three links — a missing link means an incomplete chain.
These two also settle disagreements: when a verbal description contradicts the manual, the manual prevails. A salesperson can misremember; the manual was submitted at registration.
Do not write "verified, no issues". Write five things so anyone can re-check later:
The record's value is not today. It is when the device is three years old, the contact has changed, and someone needs to re-order or transfer it — one sentence explains how the qualification was checked at the time.
Write the chain on one line: holder, manufacturer, seller. Any gap means asking for more material. This record lives as long as the device — needed for transfer, re-order and inspection.
Complete qualification only means the device may legally be marketed. It does not mean your institution may legally use it. Use involves your own scope of practice, department setup and staff qualification.
The same device placed in a health check-up department for screening and placed in a clinical department as a basis for diagnosis carries completely different requirements. Confirm the intended use with your medical and equipment departments before purchase, and write it into the purchase application. This step has nothing to do with the supplier; the responsibility is the buyer's.
If you need a verification record template for a specific model, contact the account manager with the model under consideration. Cooperation runs as direct purchase or through a dealer arrangement; details are discussed directly.
Submit an inquiry · See Xianku credentials
Note on figures: this article describes general verification practice in the Chinese market and is not legal advice. Registration details must be confirmed against the official database at the time of purchase. This article contains no pricing.
The accuracy figures and posture data discussed here all rest on the same measurement conditions: the person wears close-fitting clothing or shorts, is barefoot, stands naturally, stays as still as possible during the scan (about 3–5 seconds), and has hair tied back or pinned up so it does not cover the head and shoulder outline.
When these conditions are met, the data is used for preliminary screening, risk indication and follow-up comparison of posture and spinal status; when they are not met (loose clothing, movement, hair covering the outline), the result is an estimate for reference only. The device does not provide a medical diagnosis — any abnormal finding needs review at a medical institution.
Accuracy is millimetre-level (vendor nominal ±1 mm). A living body is not a calibration artefact: millimetre-level variation across three consecutive scans of the same person is normal, so read the trend from the range of several measurements rather than from a single number.
Specifications here come from the device datasheet and user manual — nothing is estimated or inferred.
Case data comes from client project records; organization names can be verified by phone. We do not use client names without authorization.
Qualification records can be looked up by certificate number in the National Medical Products Administration database.
Tell us how your organization works and we will route you to the manager for your sector.
If this article helped, leave your organisation and contact details and we will put together how similar institutions have handled it.
Within 30 minutes of your submission, the account manager for your sector will call you
No prices are published on this site; configuration and commercial terms are discussed one-to-one with your account manager